Sihai network

What is the reason why the booster cylinder does not act

The failure of the booster cylinder may be due to the wrong pipeline connection. Check the connecting pipeline carefully. The installation failure of the booster cylinder, the die is stuck, or the speed regulating valve is always closed, which will affect the action of the booster cylinder. We should deal with it in time.

1. Pipeline connection error

The failure of the booster cylinder may be the cause of the wrong pipeline connection. At this time, we should carefully check the connecting pipeline and reconnect the pipeline. The correct air circuit configuration diagram will be connected on the instruction manual of booster cylinder, and you can follow the steps.

2. Die stuck

In case of installation failure of booster cylinder, the die will be stuck. At this time, it will be affected by lateral force and cannot act. Timely check whether the machine mounting plate and booster cylinder are horizontal and vertical, or whether the deviation and guide column are smooth.

3. The gas circuit is blocked

Finally, we need to check whether the speed control valve is in a closed state during the process of pipeline connection. If it is, it will affect the smooth flow of gas and the action of a pressurized cylinder. It is recommended to restore the inlet valve to the fully open state in time, so that similar problems will not occur.